400 KVA Dry Transformer

400 KVA Dry Transformer
Details:
The 400kVA dry-type transformer is a medium-capacity power distribution device. Utilizing epoxy resin casting or impregnation technology, it achieves an oil-free fireproof design, making it suitable for commercial centers, factories, hospitals, and other locations with stringent safety and environmental requirements. Its core advantages include: 1. Safety & Environmental Protection No flammable liquids; meets F1 fire resistance rating (750°C high-temperature flame retardance); can be installed directly at load centers Releases no toxic substances; complies with RoHS environmental directives 2. High Efficiency & Energy Saving No-load losses reduced by 15%~30% compared to GB/T10228 national standard (e.g., SCB13/14 models) Fully sealed structure (IP2X protection rating) effectively prevents moisture/dust ingress, ensuring stable operation in tropical/coastal areas 3. Intelligent Operation & Maintenance Built-in PT100 temperature control system for real-time winding temperature monitoring (Class H insulation withstands 180°C) Equipped with remote communication interface for uploading status data to energy management systems 4. Scenario Adaptability Compact design (typical dimensions 1600×1200×1800mm) saves space Customizable on-load tap changers (±5%) or harmonic suppression solutions to address voltage fluctuations and non-linear loads With maintenance-free characteristics, a 30-year design lifespan, and ≤65dB low noise levels, this transformer has become a critical node in modern smart power grids, helping enterprises reduce TCO (Total Cost of Ownership) by over 15%.
Send Inquiry
Download
Description
Technical Parameters
Overview

 

The 400 kVA Dry Transformer is specifically engineered for the modernization of the CHE Scropoasa substation at 6.3 kV and 20 kV. It boasts maintenance-free epoxy resin insulation, a low-loss silicon steel core, and copper windings. This transformer operates using natural air cooling and allows for voltage adjustments of ±2x2.5%. It adheres to EN 60076 standards. Included accessories are a bidirectional trolley, temperature sensors, and an integrated temperature control system. The transformer is capable of handling substantial overloads and complies with the ECO Design Directive 548/2014. Comprehensive factory testing guarantees its high performance and reliability. For more information, please contact us.

 

Key Specifications

 

 

  • Power Rating: 400 kVA
  • Voltage Options:

6.3 kV Model: Primary 6.3 kV / Secondary 0.4 kV

20 kV Model: Primary 20 kV / Secondary 0.4 kV

  • Cooling System: Natural air circulation
  • Temperature Class: According to SR EN 60076-3
  • Maximum Winding Over-temperature: 100°C
  • Noise Level: 63 dB
  • Insulation: A blend of epoxy resin and quartz powder for maintenance-free operation, moisture resistance, and fire safety.
  • Core: Low-loss cold-rolled silicon steel with high magnetic permeability and minimal hysteresis and eddy current losses.
  • Windings: Copper with epoxy resin insulation, providing high mechanical strength against short-circuit forces.

 

Technical Features

 

 

  • Connection: Dyn-5
  • Adjustment: Five-step adjustment with a ±2x2.5% range on the high-voltage side, performed when the transformer is de-energized.
  • Insulation Level: F
  • Environmental Conditions:

Maximum Ambient Temperature: +40°C

Minimum Ambient Temperature: -30°C

Altitude: <1200 meters

Humidity: <100% at 20°C

Seismic Resistance: 760±15 mmHg

 

Accessories

 

 

  • Trolley: Includes bidirectional wheels with a locking mechanism.
  • Temperature Sensors: At least three PT100 sensors.
  • Temperature Control Unit: Integrated into the protection, signaling, and monitoring system
  • Lifting Lugs: For easy handling
  • Neutral Terminal: Accessible on the low voltage side for the 400 kVA, 6.3/0.4 kV transformer

 

Compliance

 

 

  • Standards: EN 60076, CEI 60076 series, IEC 60185, DIN-VDE 0414-1
  • ECO Design Directive: Fully compliant with Directive 548/2014 and its subsequent amendments.

 

Operational Flexibility

 

 

  • Overload Capability:

10% overload for 1 hour

20% overload for 30 minutes

30% overload for 15 minutes

40% overload for 8 minutes

50% overload for 4 minutes

  • Overexcitation Tolerance: Capable of operating with a maximum of 5% deviation from nominal voltage and frequency.

 

Testing

 

 

Each transformer undergoes comprehensive factory testing, including:

  • Verification of transformation ratio
  • Connection group validation
  • Measurement of winding resistance
  • Insulation resistance and absorption coefficient testing
  • Dielectric loss angle tangent measurement
  • Applied voltage and induced voltage tests
  • Measurement of no-load and short-circuit losses
  • Winding overheating and homopolar impedance measurement
  • Noise level assessment
  • Dielectric rigidity of the oil

 

 

For further details, technical support, or customized quotes, please contact our sales team. We are dedicated to delivering reliable, high-quality transformer solutions tailored to your specific needs. Reach out today to experience our outstanding service and expertise.

 

 

 

Hot Tags: 400 kva dry transformer, China 400 kva dry transformer manufacturers, suppliers, factory, transformer, Outdoor Indoor Cable Distribution Cabinet, Comprehensive Protection and Control Unit, MNS LV Withdrawable Switchgear, 10kV Heat Shrink Cable Termination, Two winding Voltage Regulation Distribution Transformer